This study analyzes 250 pelvic fracture patients treated with sacroiliac or transiliac-transsacral screw fixation over 12 years. Painful hardware was reported by 18.4% of patients, leading to implant removal at an average of 6.7 months post-surgery. All patients who underwent removal experienced significant pain reduction, with no complications recorded.