EuroIntervention | Editor's Choice

Left atrial appendage closure with the AnchorMan or Watchman devices: 12-month results of the SAFE-PROTECT randomised trial: Original Research

13 min · 5. juli 2026
episode Left atrial appendage closure with the AnchorMan or Watchman devices: 12-month results of the SAFE-PROTECT randomised trial: Original Research cover

Beskrivelse

In this episode of Editor's Choice, Dr Aaysha Cader speaks with Professor Huimin Chu about LAAC with AnchorMan versus Watchman 2.5 devices. They discuss how the 12-month results of the SAFE-PROTECT trial indicated the non-inferiority of the novel AnchorMan occluder for both primary and secondary endpoints: clinical success and LAA closure success at 1 year. This study found that the AnchorMan’s design, intended to improve sealing, resulted in significantly lower peridevice leak ≥3 mm compared to Watchman 2.5. ---------------------------------------- Hosted on Acast. See acast.com/privacy [https://acast.com/privacy] for more information.

Kommentarer

0

Vær den første til at kommentere

Tilmeld dig nu og bliv en del af EuroIntervention | Editor's Choice-fællesskabet!

Kom i gang

1 måned kun 9 kr.

Derefter 99 kr. / måned · Opsig når som helst.

  • Podcasts kun på Podimo
  • 20 lydbogstimer pr. måned
  • Gratis podcasts

Alle episoder

8 episoder

episode Left atrial appendage closure with the AnchorMan or Watchman devices: 12-month results of the SAFE-PROTECT randomised trial: Original Research cover

Left atrial appendage closure with the AnchorMan or Watchman devices: 12-month results of the SAFE-PROTECT randomised trial: Original Research

In this episode of Editor's Choice, Dr Aaysha Cader speaks with Professor Huimin Chu about LAAC with AnchorMan versus Watchman 2.5 devices. They discuss how the 12-month results of the SAFE-PROTECT trial indicated the non-inferiority of the novel AnchorMan occluder for both primary and secondary endpoints: clinical success and LAA closure success at 1 year. This study found that the AnchorMan’s design, intended to improve sealing, resulted in significantly lower peridevice leak ≥3 mm compared to Watchman 2.5. ---------------------------------------- Hosted on Acast. See acast.com/privacy [https://acast.com/privacy] for more information.

5. juli 202613 min
episode QFR versus FFR in the 2-year follow-up of FAVOR III Europe: Original Research cover

QFR versus FFR in the 2-year follow-up of FAVOR III Europe: Original Research

In this episode of Editor’s Choice, Dr Aaysha Cader speaks with Doctor Birgitte Andersen about the latest findings from the FAVOR III Europe trial, recently published in EuroIntervention. They discuss the 2-year follow-up comparing quantitative flow ratio (QFR) and fractional flow reserve (FFR), including the key outcome that QFR did not demonstrate non-inferiority at one year. Dr Andersen explores potential explanations, including concerns around reproducibility and early event rate differences, and highlights the need for further research to identify patient populations best suited for angiography-based physiological assessment. ---------------------------------------- Hosted on Acast. See acast.com/privacy [https://acast.com/privacy] for more information.

6. maj 202615 min