This podcast is made by Ran Chen, who holds an EA license, Insurance and Securities licenses (Series 6, 63, 65), and the CFP® designation. He is passionate about opening access to high-quality exam preparation resources and helping learners prepare more effectively for professional certification exams. In this episode you will learn: - System-dependent (passive) recovery uses the appliance's own compressor and is only for small appliances (15 lbs or less). - Self-contained (active) recovery has its own compressor and can be used on any size system. - For small appliances, recovery equipment must be able to capture 90% of the charge with a working compressor or 80% with a non-working one. - A common exam trap is applying the 80%/90% recovery percentages to large systems, which instead require specific vacuum levels. - An alternative to percentage-based recovery on small appliances is to pull a 4-inch mercury vacuum. For more free exam prep tools, practice questions, and AI-powered explanations, visit https://open-exam-prep.com/ or YouTube Channel: https://www.youtube.com/@Open-exam-prep