EuroIntervention | Editor's Choice

Left atrial appendage closure with the AnchorMan or Watchman devices: 12-month results of the SAFE-PROTECT randomised trial: Original Research

13 min · 5 de jul de 2026
Portada del episodio Left atrial appendage closure with the AnchorMan or Watchman devices: 12-month results of the SAFE-PROTECT randomised trial: Original Research

Descripción

In this episode of Editor's Choice, Dr Aaysha Cader speaks with Professor Huimin Chu about LAAC with AnchorMan versus Watchman 2.5 devices. They discuss how the 12-month results of the SAFE-PROTECT trial indicated the non-inferiority of the novel AnchorMan occluder for both primary and secondary endpoints: clinical success and LAA closure success at 1 year. This study found that the AnchorMan’s design, intended to improve sealing, resulted in significantly lower peridevice leak ≥3 mm compared to Watchman 2.5. ---------------------------------------- Hosted on Acast. See acast.com/privacy [https://acast.com/privacy] for more information.

Comentarios

0

Sé la primera persona en comentar

¡Regístrate ahora y únete a la comunidad de EuroIntervention | Editor's Choice!

Prueba gratis

Empieza 7 días de prueba

$99 / mes después de la prueba. · Cancela cuando quieras.

  • Podcasts solo en Podimo
  • 20 horas de audiolibros al mes
  • Podcast gratuitos

Todos los episodios

8 episodios

episode Left atrial appendage closure with the AnchorMan or Watchman devices: 12-month results of the SAFE-PROTECT randomised trial: Original Research artwork

Left atrial appendage closure with the AnchorMan or Watchman devices: 12-month results of the SAFE-PROTECT randomised trial: Original Research

In this episode of Editor's Choice, Dr Aaysha Cader speaks with Professor Huimin Chu about LAAC with AnchorMan versus Watchman 2.5 devices. They discuss how the 12-month results of the SAFE-PROTECT trial indicated the non-inferiority of the novel AnchorMan occluder for both primary and secondary endpoints: clinical success and LAA closure success at 1 year. This study found that the AnchorMan’s design, intended to improve sealing, resulted in significantly lower peridevice leak ≥3 mm compared to Watchman 2.5. ---------------------------------------- Hosted on Acast. See acast.com/privacy [https://acast.com/privacy] for more information.

5 de jul de 202613 min
episode QFR versus FFR in the 2-year follow-up of FAVOR III Europe: Original Research artwork

QFR versus FFR in the 2-year follow-up of FAVOR III Europe: Original Research

In this episode of Editor’s Choice, Dr Aaysha Cader speaks with Doctor Birgitte Andersen about the latest findings from the FAVOR III Europe trial, recently published in EuroIntervention. They discuss the 2-year follow-up comparing quantitative flow ratio (QFR) and fractional flow reserve (FFR), including the key outcome that QFR did not demonstrate non-inferiority at one year. Dr Andersen explores potential explanations, including concerns around reproducibility and early event rate differences, and highlights the need for further research to identify patient populations best suited for angiography-based physiological assessment. ---------------------------------------- Hosted on Acast. See acast.com/privacy [https://acast.com/privacy] for more information.

6 de may de 202615 min